Skip to main content

Megazyme K-GCROLGK: Glycerol GK Assay Kit

[vc_row][vc_column width=”1/2″][vc_single_image image=”6084″ img_size=”full” alignment=”center” style=”vc_box_shadow” onclick=”zoom” css_animation=”fadeIn”][/vc_column][vc_column width=”1/2″][ultimate_heading source=”post_title” heading_tag=”h3″ alignment=”left” margin_design_tab_text=””][/ultimate_heading][vc_empty_space][vc_column_text]

Product code: K-GCROLGK

[/vc_column_text][vc_column_text]The Glycerol GK test kit is a simple, reliable and accurate method for the measurement and analysis of glycerol in beverages, foodstuffs and other material. Based on use of ADP-glucokinase and increase in absorbance on conversion of NAD+ to NADH.

Note for Content: The number of manual tests per kit can be doubled if all volumes are halved.  This can be readily accommodated using the MegaQuantTM  Wave Spectrophotometer (D-MQWAVE).[/vc_column_text][vc_empty_space height=”20px”][vc_row_inner][vc_column_inner width=”1/2″][dt_button link=”https://wa.me/6281380382133″ target_blank=”true” button_alignment=”center” animation=”bounce” size=”big” icon=”JTNDaSUyMGNsYXNzJTNEJTIyZmElMjBmYS1waG9uZSUyMiUzRSUzQyUyRmklM0U=”]Call Us[/dt_button][/vc_column_inner][vc_column_inner width=”1/2″][dt_button link=”https://tsl.mwd.my.id/contact-us/” target_blank=”true” button_alignment=”center” animation=”bounce” size=”big” icon=”JTNDaSUyMGNsYXNzJTNEJTIyZmElMjBmYS1waG9uZSUyMiUzRSUzQyUyRmklM0U=”]Email Us[/dt_button][/vc_column_inner][/vc_row_inner][vc_empty_space height=”10px”][/vc_column][/vc_row][vc_row][vc_column][vc_empty_space][/vc_column][/vc_row][vc_row type=”4″][vc_column width=”1/2″][vc_empty_space height=”60px”][dt_vc_list]

Content: 70 assays (manual) / 700 assays (microplate) / 600 assays (auto-analyser)
Shipping Temperature: Ambient
Storage Temperature: Short term stability: 2-8oC,
Long term stability: See individual component labels
Stability: > 2 years under recommended storage conditions
Analyte: Glycerol
Assay Format: Spectrophotometer, Microplate, Auto-analyser
Detection Method: Absorbance
Wavelength (nm): 340
Signal Response: Increase
Linear Range: 1.0 to 35 µg of glycerol per assay
Limit of Detection: 0.37 mg/L
Reaction Time (min): ~ 7 min
Application examples: Wine (and grape juice), beer, spirits, vinegar, marzipan, fruit juices, soft drinks, toothpaste, honey, tobacco, paper (and cardboard), cosmetics, pharmaceuticals, soap and other materials (e.g. biological cultures, samples, etc.).
Method recognition: Novel method

[/dt_vc_list][/vc_column][vc_column width=”1/2″][vc_empty_space height=”60px”][vc_column_text]