Megazyme K-ACETRM: Acetic Acid Assay Kit (Acetate Kinase Manual Format)
[vc_row][vc_column width=”1/2″][vc_single_image image=”6000″ img_size=”full” alignment=”center” style=”vc_box_shadow” onclick=”zoom”][/vc_column][vc_column width=”1/2″][ultimate_heading source=”post_title” heading_tag=”h3″ alignment=”left” margin_design_tab_text=””][/ultimate_heading][vc_empty_space][vc_column_text]Product code: K-ACETRM[/vc_column_text][vc_column_text]The Acetic Acid (Acetate Kinase Manual Format) test kit is suitable for the measurement and analysis of acetic acid in food and beverages.
This rapid and reliable manual acetic acid kit is simple to perform (only two absorbance readings required), and because a true end-point is measured, does not involve complicated calculations like other kits. This product is very stable both during storage and use (> 2 years), has extended linearity (compared to ACS based kits), contains PVP to prevent tannin inhibition, and is performed at a relatively low pH (7.4), thus minimising ester hydrolysis related interference. This method is suitable for the measurement of acetic acid/acetate in foods, beverages and other materials.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).[/vc_column_text][vc_empty_space height=”20px”][vc_row_inner][vc_column_inner width=”1/2″][dt_button link=”https://wa.me/6281380382133″ target_blank=”true” button_alignment=”center” animation=”bounce” size=”big” icon=”JTNDaSUyMGNsYXNzJTNEJTIyZmElMjBmYS1waG9uZSUyMiUzRSUzQyUyRmklM0U=”]Call Us[/dt_button][/vc_column_inner][vc_column_inner width=”1/2″][dt_button link=”https://tsl.mwd.my.id/contact-us/” target_blank=”true” button_alignment=”center” animation=”bounce” size=”big” icon=”JTNDaSUyMGNsYXNzJTNEJTIyZmElMjBmYS1waG9uZSUyMiUzRSUzQyUyRmklM0U=”]Email Us[/dt_button][/vc_column_inner][/vc_row_inner][vc_empty_space height=”10px”][/vc_column][/vc_row][vc_row][vc_column][vc_empty_space][/vc_column][/vc_row][vc_row type=”4″][vc_column width=”1/2″][vc_empty_space height=”60px”][dt_vc_list]
| Content: | 72 assays (manual) / 720 assays (microplate) |
| Shipping Temperature: | Ambient |
| Storage Temperature: | Short term stability: 2-8oC, Long term stability: See individual component labels |
| Stability: | > 2 years under recommended storage conditions |
| Analyte: | Acetic Acid |
| Assay Format: | Spectrophotometer, Microplate |
| Detection Method: | Absorbance |
| Wavelength (nm): | 340 |
| Signal Response: | Decrease |
| Linear Range: | 0.3 to 25 µg of acetic acid per assay |
| Limit of Detection: | 0.254 mg/L |
| Reaction Time (min): | ~ 4 min |
| Application examples: | Wine, beer, fruit and fruit juices, soft drinks, vinegar, vegetables, pickles, dairy products (e.g. cheese), meat, fish, bread, bakery products (and baking agents), ketchup, soy sauce, mayonnaise, dressings, paper (and cardboard), tea, pharmaceuticals (e.g. infusion solutions), feed and other materials (e.g. biological cultures, samples, etc.). |
| Method recognition: | Improved method |
[/dt_vc_list][/vc_column][vc_column width=”1/2″][vc_empty_space height=”60px”][vc_column_text]