Skip to main content

Megazyme K-RAPRS: Resistant Starch Assay Kit (Rapid)

[vc_row][vc_column width=”1/2″][vc_single_image image=”5680″ img_size=”full” alignment=”center” style=”vc_box_shadow” onclick=”zoom” css_animation=”fadeIn”][/vc_column][vc_column width=”1/2″][ultimate_heading source=”post_title” heading_tag=”h3″ alignment=”left”][/ultimate_heading][vc_empty_space][vc_column_text]

Product code: K-RAPRS

[/vc_column_text][vc_column_text]The Resistant Starch Assay Kit (Rapid) method is suitable for the analysis of resistant starch in pure starch, cereal and legume seeds and food samples.

This method is an update of the method of McCleary et al1 (AOAC Method 2002.02, AACC Method 32-40.01) employing incubation conditions similar to those used in AOAC Method 2017.16 for dietary fiber. The enzyme mixture employed [pancreatic α-amylase (PAA) and amyloglucosidase (AMG)] are those used by Englyst et al.2 except that both enzymes have been purified, standardised and stabilised. Digestion is performed using saturating levels of PAA and AMG with stirring at pH 6 and 37oC for 4 h, to simulate in vivo conditions in the human small intestine. Recent studies on the hydrolysis of “newer” resistant starch materials such as phosphate crosslinked starch (RS4) indicated that these incubation conditions are an essential requirement to obtain meaningful physiologically relevant values for RS.

The incubation conditions parallel those used in AOAC Method 2017.16, a new, rapid integrated procedure for the measurement of total dietary fiber (Megazyme method K-RINTDF). This method is physiologically based and designed to service the definition of DF announced by Codex Alimentarius in 2009.[/vc_column_text][vc_empty_space height=”20px”][vc_row_inner][vc_column_inner width=”1/2″][dt_button link=”https://wa.me/6281380382133″ target_blank=”true” button_alignment=”center” animation=”bounce” size=”big” icon=”JTNDaSUyMGNsYXNzJTNEJTIyZmElMjBmYS1waG9uZSUyMiUzRSUzQyUyRmklM0U=”]Call Us[/dt_button][/vc_column_inner][vc_column_inner width=”1/2″][dt_button link=”https://tsl.mwd.my.id/contact-us/” target_blank=”true” button_alignment=”center” animation=”bounce” size=”big” icon=”JTNDaSUyMGNsYXNzJTNEJTIyZmElMjBmYS1lbnZlbG9wZS1vJTIyJTNFJTNDJTJGaSUzRQ==”]Email Us[/dt_button][/vc_column_inner][/vc_row_inner][vc_empty_space height=”10px”][/vc_column][/vc_row][vc_row][vc_column][vc_empty_space][/vc_column][/vc_row][vc_row type=”4″][vc_column width=”1/2″][vc_empty_space height=”60px”][dt_vc_list]

Content: 100 assays per kit
Shipping Temperature: Ambient
Storage Temperature: Short term stability: 2-8oC,
Long term stability: See individual component labels
Stability: > 2 years under recommended storage conditions
Analyte: Resistant Starch
Assay Format: Spectrophotometer
Detection Method: Absorbance
Wavelength (nm): 510
Signal Response: Increase
Linear Range: 4 to 100 mg of D-glucose per assay
Limit of Detection: 0.036 g/100 g
Reaction Time (min): ~ 5 h
Application examples: Plant materials, starch samples and other materials.
Method recognition: Novel method

[/dt_vc_list][vc_empty_space height=”60px”][/vc_column][vc_column width=”1/2″][vc_empty_space height=”60px”][vc_column_text][/vc_column_text][/vc_column][/vc_row]

    Comments are closed

    PT. Thermalindo Sarana Laboratoria

    Laboratory Equipment, Laboratory Safety & Laboratory Management.
    Thermalindo has been providing laboratory instruments, testing solutions, and technical services in Indonesia since 1990.

    Services

    • Project Consultation
    • Laboratory Installation
    • Equipment Training
    • After-Sales Service
    • Preventive Maintenance
    • Spare Parts
    • Technical Support
    • Laboratory Testing Services

    Industries

    • Coal & Mining
    • Power Plant
    • Cement
    • Food & Beverage
    • Agriculture & Feed
    • Environmental
    • Water & Wastewater
    • Research & Education
    • Industrial Laboratories

    Laboratory Equipment

    • Coal & Mineral
    • Environmental
    • Feed & Agriculture
    • Food & Beverage
    • Research & Development
    • Water Testing
    • Laboratory Instruments
    • Laboratory Test Kits
    • Laboratory Safety

    Contact

    Jakarta Head Office

    Jl. Panjang No. 3 & 3B, Jakarta Barat 11530 Indonesia
    Phone: +62 21 5663969, 5664037, 5663057
    Fax: +62 21 5662795
    Email: [email protected]

    Surabaya Branch Office

    Villa Bukit Mas RA-16, Jl. H. Abdul Wahab Siamin Surabaya 60225 Indonesia
    Phone: +62 31 5674739, 5674740
    Fax: +62 31 5674743
    Email: [email protected]

    Medan Branch Office

    Rukan Citraland Bagya City Blok R10/16,
    Jl. Boulevard Barat Raya, Kav. I, Percut Sei Tuan, Medan 20371 Indonesia
    Phone: +62 812 6034 4050
    Email: [email protected]

    © PT. Thermalindo Sarana Laboratoria. All Rights Reserved.
    Laboratory Equipment • Laboratory Safety • Laboratory Management